8. Technical Data
The hob is an independent Class 3 built-in unit.
This hob is category II
2H3+
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the hob.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Base of the hob.
COUNTRY OF DESTINATION: GB/IE
Gas Electric
Natural Gas 20mbar 220 240V 50Hz
Butane 29mbar
Propane 37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height
100mm;
120mm including gas connector
Above worktop 50mm;
Below worktop 50mm
Overall width
720mm; see Positioning of Cooker
Overall depth
510mm
Space for fixing
See ‘Positioning of Cooker
Minimum space above hotplate
650mm
Connections
Gas Electric
Rp ½ at rear right-hand side 220 240V 50Hz
Ratings
Natural Gas L.P. Gas
Hotplate
Injector Injector
Triple ring burner 3.5kW 141 3.5kW (255g/h) 94
Large Burners 3.0kW 129 3.0kW (218g/h) 87
Medium Burners 1.75kW 101 1.75kW (124g/h) 66
Small Burner 1.0kW 77 1.0kW (73g/h) 50
Gas burner inputs based on Gross Calorific Value
Maximum total electric load at 230V: 0.6W